Products List

Hot Blog

How Modern Cooling Tower Fill Designs Support Better Industrial Cooling Performance

How Modern Cool...

As industrial facilities continue to imp

Why Cooling Tower Fill Media Selection Is Important for Long-Term Cooling System Operation

Why Cooling Tow...

Selecting suitable cooling tower fill me

How Cooling Tower Fill Design Affects Energy Consumption in Tropical Climate

How Cooling Tow...

How Cooling Tower Fill Design Affects En

Multi-Width Cooling Tower Fill with 18mm Pitch and 5.5° Corrugation

+86 13623371227

alice@fengbeiplastic.com

Alice

Multi-Width Cooling Tower Fill with 18mm Pitch and 5.5° Corrugation

This Cooling Tower Fill is designed with multiple standard width options to provide greater flexibility for different cooling tower fill layouts. Available widths include 710mm, 720mm, 810mm, 820mm, 910mm, 920mm, 1010mm, 1020mm, 1120mm, 1220mm, 1320mm, and 1520mm, while length and thickness can be customized according to project requirements.

Multiple Width Options for Different Fill Configurations

The wide range of available widths makes this Film Fill suitable for projects requiring different module dimensions or replacement sizes. Instead of limiting a project to a single fixed width, buyers can select a suitable specification from multiple options and request customized dimensions where needed.

18mm Pitch with a 5.5° Inclined Structure

Featuring an 18mm pitch and a 5.5° angle, the fill is manufactured with a consistent corrugated structure for cooling tower applications. The defined geometry provides a standardized product configuration while allowing different widths to be supplied within the same product range.

PVC, CPVC and PP Material Options

This cooling tower fill is available in PVC, CPVC, and PP. Different material options give customers greater flexibility when specifying fill for their cooling tower projects, replacement requirements, or new equipment.

Customized Length and Thickness

Length and thickness are available on a customized basis. This allows the fill to be supplied according to the dimensions required for a particular cooling tower configuration rather than being restricted to one standard finished size.

Product Specifications

Width Range710mm, 720mm, 810mm, 820mm, 910mm, 920mm, 1010mm, 1020mm, 1120mm, 1220mm, 1320mm, 1520mm
LengthCustomized
ThicknessCustomized
Pitch18mm
MaterialPVC, CPVC, PP
Angle5.5°

A Flexible Fill Specification for Cooling Tower Projects

With multiple width choices, customizable length and thickness, an 18mm pitch, and PVC, CPVC, or PP material options, this Cooling Tower Fill provides a flexible specification for customers looking for a practical fit for different cooling tower projects. The combination of standardized corrugation and customizable dimensions also makes it suitable for both new fill requirements and replacement orders.

David Anderson / Cooling System Engineer

We purchased cooling tower fill media for our power plant cooling system upgrade. The product arrived in excellent condition and the installation process was ve

Laura Schneider / Technical Purchasing Manager

After comparing several suppliers, we selected this company because of their technical communication and product customization ability. The cooling tower fill m

Kenji Tanaka / Mechanical Engineer

The cooling tower fill quality is very consistent and meets our engineering requirements. The material design provides stable water distribution and helps maint

Ananya Patel / Project Coordinator

We ordered cooling tower fill for multiple cooling tower replacement projects. The supplier provided clear technical information, reasonable lead time, and good

What water flow conditions can your cooling tower ...
Our cooling tower fill media is designed for continuous water distribution with stable heat transfer performance. Customized fill structures can be developed to meet different cooling tower designs an
Does your cooling tower fill media support fire re...
Yes, standard PVC cooling tower fill media is designed with flame-resistant properties and tested under industry standards. Additional material options can be discussed according to specific project c
What is the standard production time for cooling t...
Typical production time is about 5–7 weeks after order approval, depending on order quantity and customization details. Flexible scheduling options can be discussed according to project requirements.
Do you provide cooling tower fill media installati...
We can assist with technical guidance and recommend experienced service partners worldwide. Remote support and on-site coordination by our engineers can also be arranged.

PROFESSIONAL COOLING TOWER FILL MANUFACTURER | QUALITY & SERVICE SUPPORT

Blog

Industry trends and cooling tower fill media insights for global customers.

Industry Trends

How Modern Cooling Tower Fill Designs Support Better Industrial Cooling Performance

How Modern Cooling Tower Fill Designs Support...

As industrial facilities continue to improve energy efficiency and equipment reliability, cooling to

Technical Support

Contact Us

Connect with our team for cooling tower fill media details, project information, and technical assistance.

Chat on WhatsApp